poster_2_up

12 VOLT SUBMERSIBLE SAMPLING PUMP

Groundwater's sampling pump with a maximum delivery height of 25 metres.

The 12V DC, 3 stages pump for groundwater’s sampling with a maximum delivery height of 25 metres is provided as standard with a 25 metres cable, equipped with two-way (male/female) terminal connectors that are easy to couple. It is also equipped with crocodile clips that are black for negative polarity and red for positive polarity. The pump is also provided with interchangeable suction filter.

  • Diameter: 46 mm

  • Lenght: 450 mm

  • Body pump: PVC

  • Max flow rate: 12 L/M

  • Max delivery rate: 25 m

  • Cable diameter: 10 mm

Product page

poster_2_up

EVO 12 VOLT SUBMERSIBLE SAMPLING PUMP

Groundwater's sampling pump with a maximum delivery height of 50 metres.

The 12V DC, 5 stages pump for groundwater’s sampling with a maximum delivery height of 50 metres is provided as standard with a 50 metres cable, equipped with two-way terminal connectors, easy to couple, which can be used only with the 12V Pump Booster. The pump is also equipped with an interchangeable suction filter.The 12V DC, 5 stages pump is a multistage pump working with counterclockwise rotation, directly coupled to special submersible engines. The pump achieves the performance indicated in the table below only with fully charged battery. When the voltage indicator on the Pump Booster signals a value equal to or less than 11,5V, it is necessary to replace the battery with a fully charged one. In case of use with low battery, the pump could be irredeemably damaged. It is essential to always control that the positive ( ) and negative (-) polarities are respected on the 12V Pump Booster. It is recommended not to modify the cable length in any way. Do not use the pump in case of: pumping of liquids other than water, presence of silt or sand in the water, dry running, use for prolonged periods of more than 20 minutes.  EVO 12VDC PUMP bar 1 2 3 4 4,5 liters / min 11 8,3 5,5 3,5 2,2Supply voltage                        12VDCOperating voltage           24VDCIntensity                                   15 Amp

  • Diameter: 48 mm

  • Length: 730 mm

  • Pump body: PVC

  • Max flow rate: 11 L/M

  • Max delivery height: 50 M

  • Diameter cable connection: 10 mm

Product page

poster_2_up

12V DC AUTOMATIC SUBMERSIBLE PUMP FOR THE RECOVERY OF LNAPL

12 V automatic and submersible pump for the recovery of LNAPL.

HYDRO/P1A is a device for the recovery of LNAPL, equipped with elements dedicated to the recognition of air/water/product and stop and automatic restart systems. The device works with AC 220V electrical control panel that controls the pick-up equipment, which operates in DC 12V. The equipment is provided with a maximum delivery height of 5 bars (reference data: flow rate of 2,0 l/min with 1 bars delivery height). The control panel is normally made in IP55 version for outdoor installation; if required, it can be made in an explosion-proof Exd version. The components of the recognition system of air/water/product (floaters) form an intrinsically safe circuit Exia (double level floater Exia, driven by an isolated dual channel barrier Exia) with a protection up to two independent failures in the system. The device has a maximum delivery height of 55 metres and it is provided as standard with a 20 metres cable that is equipped with two interchangeable metal mesh filters.

  • Diameter: 48 mm

  • Lenght: 430 mm

  • Body pump: acciaio inox AISI 304

  • Max flow rate: 2 L/min

  • Max delivery rate: 55 m

  • Cable diameter: 10 mm

Product page

poster_2_up

12V Low Flow Controller

12V Low Flow Controller for the 12V Sampling Pump and the 12v Vacuum Pump.

The Low Flow Controller 12V is a voltage/Ampère changer. It can work with the 12V Submersible Sampling Pump (mod. Hydrogea) or with the 12V Vacuum Pump. It allows to vary the rotation speed of the rotor and therefore the sampling pump flow or of the vacuum pump flow. The controller achieves the performance indicated below only with a fully charged battery. Always control that the positive ( ) and negative (-) polarities of the battery are respected. Do not use the controller in case of: liquids presence or use for prolonged periods of more than 1 continuous hour. USEIt is recommended to verify that the voltage controller is not exposed to water. Connect the Low Flow Controller 12V to the power supply entering its male and female bipolar connectors between the 12V Sampling Pump or the 12V  Vacuum Pump and the two clips, making sure that the polarities are respected. Switch on the controller via the changer/switch. Switch off the circuit always via the changer/switch. The Low Flow Controller 12V is protected by a 12A fuse. 

  • Rated operating voltage: 12V DC

  • Maximum absorption: 10 Amp

  • Electric power: 120 W

  • Fuse: 12 A

Product page

poster_2_up

EVO 12 V PUMP BOOSTER

Flux regulator for the EVO pump with 50 metres delivery height.

The 12V EVO Pump Booster is a flux regulator exclusively dedicated at the use of the EVO 12V DC pump with 50 metres delivery height. It is equipped with two-poles female connectors that can be used only with the EVO 12V DC pump. The power supply requires a 12V battery (as for a car: the two pliers must be linked respecting the polarities red ( ) and black (-) on the battery). In case of incorrect use of the indicated polarities, the regulator is furnished with a fuse protection. The 12V Pump Booster regulator is supplied with a display indicating the battery charge during its use. When the voltage indicated on the display is equal to or less than 11,5V, it is mandatory to stop immediately the pumping in order to prevent the battery from being irremediably damaged. The battery must be replaced with a fully charged one. The regulation is carried out by the knob that serves as a switch. Do not connect the battery with the switch on. 

  • Power supply: 12V

  • Output voltage: 20V

  • Absorption: 30A 


Product page

poster_2_up

PNEUMATIC PUMP TOTAL FLUID TOP INLET 2"

Pneumatic submersible pump top inlet 2”.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven.This pump is used for the extraction of water from the bottom of wells orpiezometers or liquids with lower density than water. Adjustable pulses of compressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The compressed air pulses and, therefore, the control of the pump are started by a panel, that can be electric or pneumatic as well. This panel is essential in order to allow the functioning of all The pump consists of a bronze head, a bronze pad,a connection for the entry of compressed air, a non-return valve for the flowof liquids, a ball non-return valve for the top loading. 

  • External diameter: 48,3 mm

  • Max flow rate: 10 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 m

Product page

poster_2_up

ACTIVE SKIMMER

Submersible pump for the recovery of LNAPL

The active skimmer is a submersible pump pneumatically driven which is specific for the recovery of LNAPL. The pump is equipped with a floating mechanism that allows the entry of only LNAPL, if it is present. The active skimmer consists of a reamer (skimmer) devoted to the separation of water/oil, equipped with a floater for the recovery with gravity. Another fundamental part of the active skimmer system is a pumping unit situated below the skimmer and useful to send the product to the superficie through ON/OFF cycles of compressed air (total fluid pumps). The recovery of product happens with gravity, indeed its efficacy depends on the combination of viscosity and initial thickness. Under the best conditions of viscosity and initial thickness, the active skimmer is able to visibly reduce the layer of LNAPL. The total length of the active skimmer is 180 cm, of which, 40,5 cm constitute the useful floating part.

  • Materials: fiberglass, steel, Viton, tygon

  • External diameter: 48 mm

  • Specific gravity of extracted product: ≤ 0,85 g/cm3

  • Kinematic viscosity: 1-1000 cSt

  • Initial thickness of the product: from 20 mm to 70 mm (depending on the viscosity)

Product page

poster_2_up

PNEUMATIC PANEL FOR PNEUMATIC PUMPS

The pneumatic panel for pneumatic pumps allows the pneumatic system to carry out the ON/OFF cycle of compressed air.

The pneumatic panel for pneumatic pumps can be combined to various pneumatic systems:pneumatic pump total fluid top inlet 2” pneumatic pump total fluid top inlet 3” pneumatic pump total fluid bottom inlet 2”active skimmer.The pneumatic panel allows the pneumatic system to carry out the ON/OFF cycles of compressed air, fundamental for its proper functioning. The pneumatic panels for pneumatic pumps work thanks to the same compressed air that allows the functioning of the pneumatic pump/s connected to it. The electric power is not needed. The regulation of the ON/OFF cycles is accomplished by two rotary selectors situated inside the panel. The ON selector should be activated for a period of time that goes from 0 to 30 seconds (depending on the inlet pressure that should be between 2 and 5 bars), the same is valid for the OFF selector (0 to 30 seconds). It is possible to connect up to four pneumatic pumps to each pneumatic panel, in that case all pumps would have the same regulation of ON/OFF times. It is possible to increase up to 30 minutes the OFF times by adding a lung. There is a floating pneumatic valve (pneumatic level switch) that allows to close mechanically the pneumatic feeding circuit of the pneumatic panel in case, for example, of the filling of a storage tank.

  • Dimensions: 32 x 24 x 13

  • Minimum pressure: 2.5 bar

  • ON regulation: 30"

  • OFF regulation: 30" (It is possible to increase up to 30 minutes the OFF times by adding a lung.)

Product page

poster_2_up

PASSIVE SKIMMER

Submersible trap specific for the recovery of LNAPL.

The passive skimmer is a submersible trap specific for the recovery of LNAPL. The system is provided with a floating mechanism suitable to the fluctuations of the aquifer, which allows the entry of LNAPL, and a collecting tank for the product itself. The passive skimmer consists of a reamer (skimmer) dedicated to the oil / water separation, equipped with a float for the recovery with gravity. Another constituent part of the passive skimmer system is the collecting tank, located below the skimmer, useful to trap the floating product. The recovery of product happens with gravity; therefore, the effectiveness depends on the combination of viscosity and initial thickness. In the best conditions of viscosity and initial thickness, the passive skimmer is able to visibly reduce the layer of floating product. The passive skimmer must be manually extracted and emptied from the well. The total length of the passive skimmer is 180 cm and, of these, 40.5 cm constitute the effective skimming travel.

  • Materials: fiberglass, steel, Viton, tygon

  • External diameter: 60 mm

  • Specific gravity of extracted product: ≤ 0,85 g/cm3

  • Kinematic viscosity: 1-1000 cSt

  • Initial thickness of the product: from 20 mm to 70 mm (depending on the viscosity)

Product page

poster_2_up

PNEUMATIC PUMP TOTAL FLUID TOP INLET 3"

Pneumatic submersible pump top inlet 3”.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven. This pump is used for the extraction of water from the bottom of wells or piezometers or liquids with density lower than water. Adjustable pulses of compressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The pump consists of a bronze head, a bronze pad, a connection for the entry of compressed air, a non-return valve for the flow of liquids, a ball non-return valve for the top loading.  

  • External diameter: 76 mm

  • Max flow rate: 10 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 mt

Product page

poster_2_up

VACUUM PUMP 12 V

Air sampling pump.

The 12V Vacuum pump is a gas booster for the bleeding and sampling of air (both atmospheric air and soil gas). TECHNICAL DATAThe 12V Vacuum pump is a piston vacuum pump. It can work with the 12V Controller (mod. Hydrogea) that allows to vary the rotation speed of the rotor and therefore the flux of the vacuum pump. The aspiration system is equipped with a forced cooling system through a fan. Four suction sampling lines can be connected at the same time with the possibility of adjustment on each line. Three lines with  flow meter scales from 0 to 1 litre per minute, one line with a flow meter scale from 0 to 5 litres per minute. A sample outlet on delivery to the vacuum pump allows a possible analysis of the outgoing gases.The pump achieves the performance indicated on the table below only with a fully charged battery. Controlling that the positive ( ) and negative (-) polarities are respected is essential. It is recommended not to modify the cable length in any way. Do not use the vacuum pump in case of: pumping of liquids, presence of dust in the air (in this case the use of dust filters is suggested), use for prolonged periods of more than one continuous hour. USEBefore use, verify that the well, the line, the gas probe (soil gas) do not present any risk of liquid drafting by the vacuum pump.Place the case so that the lid is open and the flowmeters are in vertical position.Connect the vacuum pump to the power supply, always making sure the respect of the polarities /- . Choose a gas line (diameter 8 mm) for each flowmeter to connect and regulate each line flow. The suction flow varies according to the pressure drops (an increased length of the tube or the adding of an ampoule will certainly change the initial flow rate). 

  • Dimensions: 35 x 30 x 15 cm 

  • Weight: 4 kg

  • Power supply: 12V

  • Electric power consumption: 0,7 A 

  • Maximum combined flow: 8 l/min

  • Minimum flow: 0,1 l/min

  • Power autonomy: dependent on the type of battery 

Product page

poster_2_up

MANUAL 12V FREE PHASE PETROLEUM CONTAMINATION 2” RECOVERING PUMP

12V DC portable and manual pump for the recovery of LNAPL.

The pump is meant to be used in manual picking operations of hydrocarbons from the free surface of industrial water wells. The portable system works in DC 12V and it is usually powered by a battery; The 12V DC portable and manual pump for th recovery of LNAPL has a maximum delivery height of 55 metres and it is provided as standard with a 20 metres cable, black crocodile clip for the negative polarity and red one for the positive polarity. The pump is also equipped with an interchangeable metal mesh filter.

  • Diameter: 48 mm

  • Length: 300 mm

  • Pump body: ACCIAIO INOX AISI 304

  • Max flow rate: 1,6 L/min

  • Max delivery height: 55 m

  • Diameter cable connection: 10 mm

Product page

poster_2_up

ELECTRIC PANEL FOR PNEUMATIC PUMPS

The electric panel allows the pneumatic system to carry out the ON/OFF cycles of comrpessed air.

The electric panel for pneumatic pumps can be combined to various pneumatic systems: pneumatic pump total fluid top inlet 2”pneumatic pump total fluid top inlet 3”pneumatic pump total fluid bottom inlet 2”active skimmer.The electric panel allows the pneumatic system to carry out the ON/OFF cycles of compressed air, fundamental for its proper functioning. The electric panels for pneumatic pumps (IP55) are charged by 230V alternating energy and they can be arranged for one or more command lines. Each line is regulated by a solenoid valve and an ON/OFF regulating timer. It is possible to connect up to four pneumatic pumps to a single line; in that case, each pump would have the same regulation of the ON/OFF times. Hydrogea predisposes all panels with a Tank Full contact that closes the solenoid valve/s in case, for example, of the filling of a storage tank. The regulation of the ON/OFF times, that open or close the 230V solenoid valve, positioned outside the panel, is implemented by a double ON/OFF rotary selector. The compressed air that feeds the pneumatic pump is connected at the entry of the solenoid valve, whose exit is connected to the entry of the pneumatic pump. The cyclic and repeated action of opening (ON) and closing (OFF) of the solenoid valve allows the pump to function. The regulation of the ON/OFF times depends on the flow desired. Hydrogea normally suggests ON times sufficiently short to empty the pneumatic pump.

fewfw

Product page

poster_2_up

PNEUMATIC PUMP BOTTOM INLET 2"

Pneumatic submersible pump total fluid bottom inlet.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven.This pump is used for the extraction of water from the bottom of wells orpiezometers or liquids with density higher than water. Adjustable pulses ofcompressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The pump consists of a bronze head, a bronze pad,a connection for the entry of compressed air, a non-return valve for the flowof liquids and a ball non-return valve for the bottom loading.

  • External diameter: 48,3 mm

  • Max flow rate: 20 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 mt

Product page

poster_2_up

PNEUMATIC LEVEL SWITCH

Level switch for pumping and storage pneumatic systems.

The Pneumatic Level Switch is used with pneumatic pumping and storage systems. It consists of a rod connected to a float that opens/closes a valve positioned on the delivery line of compressed air towards the pneumatic pump (pneumatic submersible pump top inlet 2", pneumatic submersible pump top inlet 3", pneumatic submersible pump bottom inlet 2") or towards the active skimmer. Thereby, even without electric power in the site of the system, the pumping is stopped in case of filling of the storage tank. The Pneumatic Level Switch must be positioned between the source of compressed air and the pneumatic panel for pneumatic pumps. The Pneumatic Level Switch does not require electric power. 

  • Dimensions: total length = 45 cm, rod length = 35 cm (the rod length can be reduced to 15 cm) 

  • Minimum pressure: 3 bar 

Product page